RotorAlert
Incidents🇬🇧 United Kingdom2021-03-04
Incident report

Leonardo AW189 crash near 3 nm south-east of Porthcawl, Wales, United Kingdom

minor2021-03-04
Summary

While returning from a SAR training sortie, shortly after selecting the cabin and cockpit heating ON, a heating duct failed causing fragments of duct insulation material to be discharged through the heating vents. The heating system was turned OFF but the subsequent presence of smoke, and a smell of burning, prompted an emergency landing. Several weeks later, a similar heating duct failure occurred on another of the operator’s AW189 helicopters. The occupants of both helicopters suffered respiratory irritation. The investigation determined that the heating ducts failed due to non-uniform adhesion at joints between rigid and flexible sections of duct. Interim safety action taken by the manufacturer includes the publication of a Service Bulletin to inspect and modify the installation of the heating duct. A further heating duct failure occurred on another AW189 following embodiment of the Service Bulletin and that event will be reported separately by the AAIB. At the time of publication of this report, the investigation into the recent duct failure is ongoing and the aircraft manufacturer is continuing to work with the duct manufacturer to achieve a permanent design solution. Leonardo AW189, G-MCGU 04-22

Incident details
Date
2021-03-04
Location
3 nm south-east of Porthcawl, Wales, United Kingdom
Registration
G-MCGU
Operator type
commercial
Fatalities
0
Injuries
0
Probable cause
Phase of flight
cruise
Quick stats
Severityminor
Fatalities0
Injuries0
SourceAAIB
Other incidents in United Kingdom
← Back to all incidents